WAUKEE ENGINEERING CO INC -- COMPRESSOR OIL -- 9150-01-087-3990
===================== Product Identification ===================== Product ID:COMPRESSOR OIL MSDS Date:10/01/1995 FSC:9150 NIIN:01-087-3990 === Responsible Party === Company Name:WAUKEE ENGINEERING CO INC Address:5600 WEST FLORIST AVE City:MILWAUKEE State:WI ZIP:53218 Country:US Info Phone Num:414-462-8200 Emergency Phone Num:414-462-8200 CAGE:29827 === Contractor Identification === Company Name:WAUKEE ENGINEERING CO INC Address:5600 WEST FLORIST AVE Box:City:MILWAUKEE State:WI ZIP:53218 Country:US Phone:414-462-8200 CAGE:29827 ============= Composition/Information on Ingredients ============= Ingred Name:BASE OILS CONTAINING INGREDIENT 1 AND/OR 2 RTECS #:9999999ZZ Fraction by Wt: 95% OSHA PEL:N/K ACGIH TLV:N/K Ingred Name:PETROLEUM DISTILLATES; (DISTILLATES (PETROLEUM), HYDROTREATED HEAVY PARAFFINIC) OSHA PEL:N/K ACGIH TLV:N/K Ingred Name:PETROLEUM DISTILLATES; (DISTILLATES (PETROLEUM), SOLVENT-REFINED HEAVY PARAFFINIC) OSHA PEL:N/K ACGIH TLV:N/K Ingred Name:PHOSPHORIC ACID ESTERS; (PHOSPHORIC ACID, TRIS (METHYLPHENYL) ESTER) Fraction by Wt: 0.05% OSHA PEL:N/K ACGIH TLV:N/K Ingred Name:PHOSPHORODITHOIC ACID, O-O-D1 C1-14-ALKYL ESTERS, ZINC SALTS (2:1) (ZDDP) CAS:68649-42-3 Fraction by Wt: 0.06% OSHA PEL:N/K ACGIH TLV:N/K Ingred Name:SPILL PROC: TO APPROP AUTHS. US COAST GUARD REGS REQUIRE IMMED REPORTING OF SPILLS THAT COULD REACH ANY WATERWAY (ING 7) RTECS #:9999999ZZ Ingred Name:ING 6: INCLUDING INTERMITTENT DRY CREEKS. REPORT SPILL TO COAST GUARD TOLL FREE NUMBER 1-800-424-8802. IN CASE (ING 8) RTECS #:9999999ZZ Ingred Name:ING 7: OF ACCIDENT OR ROAD SPILL NOTIFY CHEMTREC 1-800-424-9300. RTECS #:9999999ZZ Ingred Name:WASTE DISP METH: OR CAN BE DISPOSED OF AT ANY GOVT APPROVED WASTE DISPOSAL FACILITY. USE OF THESE METHODS IS (ING 10) RTECS #:9999999ZZ Ingred Name:ING 9: SUBJECT TO USER COMPLIANCE WITH APPLIC FEDERAL, STATE & LOCAL LAWS & REGS & CONSIDERATION OF PROD (ING 11) RTECS #:9999999ZZ Ingred Name:ING 10: CHARACTERISTICS AT TIME OF DISPOSAL. RTECS #:9999999ZZ ===================== Hazards Identification ===================== LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER. Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:SLIGHT SKIN IRRITATION. SUBCHRONIC TOXICOLOGY: SEVERELY SOLV REFINED & SEVERELY HYDROTREATED MINERAL BASE OILS HAVE BEEN TESTED BY DERMAL APPLICATN TO RATS 5 DAYS/WK FOR 90 DAYS AT DOSES SIGNIFICANTLY HIGHER THAN THOSE EXPECTED DURING NORMINDUSTRIAL EXPOS. EXTENSIVE EVALUATIONS INCLUDING MICROSCOPIC (EFTS OF OVEREXP) Explanation of Carcinogenicity:NOT RELEVANT Effects of Overexposure:HLTH HAZ: EXAM OF INTERNAL ORGANS & CLINICAL CHEM OF BODY FLUIDS SHOWED NO ADVERSE EFTS. CHRONIC TOXICOLOGY: THE BASE OILS IN THIS PROD ARE SEVERELY SOLVENT REFINED AND/OR SEVERELY HYDROTREATED. CHRON IC MOUSE SKIN PAINTING STUDIES OF SIMILAR OILS SHOWED NO EVIDENCE OF CARCINOGENIC EFFECTS. Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER. ======================= First Aid Measures ======================= First Aid:INHAL: REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE OXYGEN/ARTIFICIAL RESPIRATION) . EYES: FLUSH THOROUGHLY WITH WATER FOR AT LEAST 15 MINUTES. IF IRRITATION PERSISTS, CALL MD. SKIN: WASH CONTAC T AREAS WITH SOAP AND WATER. INGESTION:NOT EXPECTED TO BE A PROBLEM WHEN INGESTED. IF UNCOMFORTABLE SEEK MEDICAL ASSISTANCE. ===================== Fire Fighting Measures ===================== Flash Point Method:COC Flash Point:>405F,>207C Lower Limits:0.6% Upper Limits:7.0% Extinguishing Media:CARBON DIOXIDE, FOAM, DRY CHEMICAL AND WATER FOG. Fire Fighting Procedures:USE NIOSH APPRVD SCBA & FULL PROT EQUIP . WATER OR FOAM MAY CAUSE FROTHING. USE WATER TO KEEP FIRE EXPOSED CNTNRS COOL. WATER SPRAY MAY BE USED (SUPDAT) Unusual Fire/Explosion Hazard:NONE. ================== Accidental Release Measures ================== Spill Release Procedures:ABSORB ON FIRE RETARDANT TREATED SAWDUST, DIATOMACEOUS EARTH, ETC. SHOVEL UP & DISPOSE OF AT AN APPROP WASTE DISP FACILITY I/A/W CURRENT APPLIC FED, STATE & LOCAL LAWS & REGS & PROD CHARACTERISTICS AT TIME OF DISPOSAL. REPORT SPILLS AS REQD (ING 6) Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:NO SPECIAL PRECAUTIONS REQUIRED. Other Precautions:NONE SPECIFIED BY MANUFACTURER. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:NO SPECIAL REQUIREMENTS UNDER ORDINARY CONDITIONS OF USE AND WITH ADEQUATE VENTILATION. USE NIOSH APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN . Ventilation:NO SPECIAL REQUIREMENTS UNDER ORDINARY CONDITIONS OF USE AND WITH ADEQUATE VENTILATION. Protective Gloves:IMPERVIOUS GLOVES . Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES . Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER . Work Hygienic Practices:GOOD PERSONAL HYGIENE PRACTICES SHOULD ALWAYS BE FOLLOWED. Supplemental Safety and Health FIRE FIGHT PROC: TO FLUSH SPILLS AWAY FROM EXPOSURE. FOR FIRES IN ENCLOSED AREAS, FIREFIGHTERS MUST USE NIOSH APPRVD SCBA. PREVENT RUNOFF FROM FIRE CONTROL OR DILUTION FROM ENTERING STREAMS, SEWERS OR DRINKING WATER SUPPLY. ================== Physical/Chemical Properties ================== Boiling Pt:B.P. Text:>600F,>316C Vapor Pres:<0.1 @ 20C Spec Gravity:0.87 Solubility in Water:NEGLIGIBLE Appearance and Odor:LIGHT AMBER LIQUID; MILD ODOR. ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES STRONG OXIDIZERS. Stability Condition to Avoid:EXTREME HEAT. Hazardous Decomposition Products:CARBON MONOXIDE. ==================== Disposal Considerations ==================== Waste Disposal Methods:PROD IS SUITABLE FOR BURNING IN AN ENCLOSED, CONTROLLED BURNER FOR FUEL VALUE OR DISPOSAL BY SUPERVISED INCINERATION. SUCH BURNING MAY BE LIMITED PURSUANT TO RCRA. IN ADDN, THE PROD IS SUITABLE FOR PR OCESSING BY AN APPROVED RECYCLING FACILITY (ING 9) Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.